[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 9, Issue 2 (10-2012) ::
Mod Care J 2012, 9(2): 80-86 Back to browse issues page
Evaluation of blood cell count in the radiology staff of Birjand Hospitals in 2011
Mahmoodreza Tavakkoli , Mahbobeh Moradalizade , Gholamreza Ananisarab , Seyed Mahmood Hosseini
, smhosseini39@yahoo.com
Abstract:   (5018 Views)
Background and Aim: Ionizing radiation can cause irreversible damages in individuals who are somehow exposed to radiation. Counting blood cells (CBC) can be used as a criterion to reveal the extent of injury to the hematopoietic system by ionizing rays. The present study aimed at examining blood cells of the radiology staff in the radiology wards of Birjand hospitals in 2011. Materials and Methods: In this case-control study, 36 radiology staff of Birjand radiology wards (cases) and 36 individuals who worked in other wards and had nothing to do with radiation but were matched with the cases regarding intervening variables were assessed. Cell blood count was measured by means of sysmix machine. The obtained data was analysed at the significant level P= 0.05 using SPSS (V.16) using statistical tests independent-T, one-way variance, and Pearson’s correlation coefficient. Results: The study population covered 18 males and 18 females. Mean white blood cells and monocytes in radiation personnel were lower compared to that of the control group. No significant correlation was observed between age, gender, educational level, and working record on hand with blood cell count, on the other. Conclusion: Regarding ever- increasing of ionizing radiation use in Medical Imaging, it is necessary to observe standards and more accurately in medical radiology centers, especially in nuclear medicine. Besides, the present study indicates that radiation exposure must seriously be followed up by authorities in charge.  
Keywords: Radiation, Ionizing, Blood Cells, X-Rays, Occupational Diseases, Occupational Exposure, Allied Health Personnel
Full-Text [PDF 222 kb]   (3243 Downloads)    
Type of Study: Systematic Review |
Received: 2012/09/15 | Accepted: 2012/10/1
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Tavakkoli M, Moradalizade M, Ananisarab G, Hosseini S M. Evaluation of blood cell count in the radiology staff of Birjand Hospitals in 2011 . Mod Care J. 2012; 9 (2) :80-86
URL: http://moderncare.bums.ac.ir/article-1-39-en.html


Volume 9, Issue 2 (10-2012) Back to browse issues page
مراقبتهای نوین Modern Care Journal
Persian site map - English site map - Created in 0.16 seconds with 30 queries by YEKTAWEB 3760