The Impact of Linear Sodium-Ultrafiltration Profiling on Hemodialysis Tolerance
Borzou, Farmani, Salvati , Gholyaf, Mahjoub
MSc of Nursing , salavati@umsha.ac.ir
Abstract:   (1988 Views)

 

Background and objective: Low blood pressure and muscle cramps are the most common complications of hemodialysis. These complications during hemodialysis cause patient intolerance. One approach that has recently been proposed to prevent this complication of dialysis is to change dialysate sodium concentration and remove the velocity of fluid, a procedure called sodium-ultrafiltration profile. The purpose of this study was to investigate the effect of linear sodium-ultrafiltration profile on the patient's tolerance during hemodialysis.

 Material and Methods: This was a clinical trial with a crossover design. 30 hemodialysis patients referring to Be’sat Hemodialysis Center in Hamadan who had inclusion criteria were selected. Each of the patients received routine treatment for two sessions (where dialysate sodium concentration of 138 mmol/l remains constant from the first to the last day of dialysis, and ultrafiltration rate will not change) and two sessions of Profile 1 Na plus profile 1 ultrafiltration upon the physician’s order (sodium concentration dialysate at the beginning of dialysis was 146 mmol/l which was linearly decreased at the end of dialysis to 138 mmol/l ultrafiltration also decreased in an automated and linear manner over dialysis). Data were analyzed in SPSS (version 16) using Paired t -Test, ANOVA with repeated observations, Tukey Post Hoc and Wolcoxon.

 Results: The mean age of patients was 50.83±16.71 years, and 53.3% were female. The results showed that the incidence of hypotension was significantly reduced during linear profiles, as compared with controls (P<0.05). And comfort level in the linear profile sodium-ultrafiltration was more. However, there was no significant difference between the incidences of muscle cramps in the two procedures.

 Conclusion: Given the simplicity, cost-effectiveness, and reduced complications of sodium and ultrafiltration profiles during dialysis, we recommend using sodium and UF profiles instead of the routine method.

 

Keywords: Hemodialysis, Sodium profile, Ultrafiltration, Patient tolerance
Full-Text [PDF 335 kb]   (919 Downloads)    
Type of Study: Experimental | Subject: Nursery
Received: 2014/01/4 | Accepted: 2014/04/13 | Published: 2015/06/24
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Borzou, Farmani, Salvati, Gholyaf, Mahjoub. The Impact of Linear Sodium-Ultrafiltration Profiling on Hemodialysis Tolerance. Mod Care J. 2014; 11 (4) :283-292
URL: http://moderncare.bums.ac.ir/article-1-599-en.html
Volume 11, Number 4 (6-2014) Back to browse issues page
مراقبتهای نوین Modern Care Journal
Persian site map - English site map - Created in 0.246 seconds with 821 queries by yektaweb 3501